"ANENG LCD Digital Multimeter 6000 Counts Backlight AC/DC Ammeter Voltmeter Ohm Portable Voltage Meter
Specifications:
Size: 130*66*30mm/5.12*2.6*1.18\""
Material: PP
Weight: 130g
Color:Blue

Safety Information:
This Multi-meter has been designed according to IEC-1010 concerning electronic measuring instruments with an overvoltage category (CAT II) and pollution 2.
Follow all safety and operating instructions to ensure that the meter is used safety and is kept in good operating condition.
Full compliance with safety standards can be guaranteed only with test leads supplied if necessary; they must be replaced with the type specified in this manual.

Safety Symbols:
Important safety information, refer to the operating manual.
Dangerous voltage may be presented.
Earth ground.
Double insulation (Protection class II).
Maintenance:
Before opening the case, always disconnect test leads from all energized circuits .
For continue protection against fire :replace fuse only with the specified voltage and current ratings :F 250mA/250V(Quick Acting) Self-restoring fuse
Never use the meter unless the back cover is in place and fastened completely.
Do not use abrasives or solvents on the meter .To clean it using a damp cloth and mild detergent only.

During Use:
Never exceed the protection limit values indicated in specifications for each range of measurement.
When the meter is linked to measurement circuit ,do not touch unused terminals .
Never use the meter to measure voltages that might exceed 600V DC or 600V AC Above earth ground in category II installations.
When the value scale to be measured is unknown beforehand, set the range selector at the highest position.
Before rotating the range selector to change functions ,disconnect test leads from the circuit under test .
When carrying out measurements on TV or switching power circuits always remember that there may be high amplitude voltages pulses at test points ,which can damage the meter .
Always be careful when working with voltages above 60V DC or 36V AC rms .Keep finger behind the probe barriers while measuring.
Before attempting to insert transistors for testing, always be sure that test leads have been disconnected from any measurement circuits.
Components should not be connected to the hFE socket when marking voltage measurements with test leads.
Never perform resistance measurements on live circuits.

General Description:
The meter is a hand held 3 1/2 digital multi-meter for measuring DC and AC voltage, DC and AC current, Resistance, Diode, Transistor and Continuity Test with battery operated. For special models also can be used for testing frequency, temperature, capacitance and NCV.

Specifications:
Accuracy is specified for a period of one year after calibration and at 18℃ to 28℃(64℉ to 82℉)with relative humidity to 80%.
General:
Maximum voltage between terminals and earth ground: 600V DC or 600V AC
Fuse protection : F 250mA/250V Self-restoring fuse
Power : 9V battery, NEDA 1604 or 6F22
Display: LCD, 1999 counts, updates 2-3 times per second
Measuring method: Dual-slope integration A/D converter
Over range Indication : Only figure\""1\"" on the display
Poladty indication : \""-\""display for negative polarity
Operating Environment : 0 to 40℃
Storage temperature: -10 to 50℃
Low battery indication:  appears on the display
Size :32*63*130mm/1.26*2.48*5.12\""
Weight: Approx. 215g
DC Voltage:
Overload Protection: 250V rms for 200mV range, and 600V DC or rms AC for other ranges.
AC Voltage (2V and 20V ranges special model only)
Overload Protection: 600V DC or AC rms .
DC Current:
Overload Protection: 250V DC or AC rms for all ranges.
Overload Protection: F250mA/250V fuse. (10A range unfused)
AC Current  (special model only)
Overload Protection: 250V DC or AC rms for all ranges.
Overload Protection: F250Ma/250V fuse. (10A range unfused)
Resistance(20MΩ and 200MΩ ranges special model only)
Maximum Open circuit Voltage: 3.2V
Overload Protection: 250V DC or AC rms for all ranges.
Capacitance (special model only)
Overload Protection: 250V DC or AC rms for all ranges.
Overload Protection: F250Ma/250V fuse. 

Operating Instructions:
DC Voltage Measurement:
1.Connect the red test lead to the \""VΩmA\"" jack and the black test lead to the \""COM\"" jack.
2.Set rotary switch at DCV position. If voltage to be measured is unknown, set range switch at the highest range position and then reduce it until satisfactory resolution is obtained.
3.Connect test leads across the source or load being measured.
4.Read voltage value on the LCD display along with the polarity of red lead connection.

Current Measurement:
1.Connect the red test lead to the \""VΩmA\"" jack and the black test lead to the \""COM\""jack. (For measurements between 200mA and 10A, remove red lead to \""10A\"" jack.
2.Set the rotary switch at desired DCA position.
3.Open the circuit in which the current is to be measured and connect test leads in series with the circuit.
4.Read current value on LCD display along with the polarity of red lead connection.

AC Voltage Measurement:
1.  Connect the red test lead to the \""VΩmA\""jack and the black test lead to the \""COM\"" jack.
2.Set the rotary switch at desired ACV position.
3.Connect test leads across the source or load being measured.
4.Read voltage value on LCD display.

Resistance Measurement:
1.Connect the red test lead to the \""VΩmA\"" jack and the black test lead to the \""COM\"" jack. 
2.Set the rotary switch at desired Ω position.
3.Connect test leads across the resistor to be measured and read the value on LCD display.
4.If the resistor being measured is connected to a circuit, turn off the power and discharge all capacitors before applying test probes.

Diode Test:
1.Connect the red test lead to the \""VΩmA\""jack and the black test lead to the \""COM\"" jack. (The polarity of red lead is positive \""+\"")
2.Set the rotary switch at position.
3.Connect the read test lead to the anode of the diode to be tested and the black test lead to the cathode of the diode. The approx, forward voltage drop of the diode will be displayed. If the connection is reversed. Only figure \""1\"" will be shown.

Transistor Test:
1.Set the rotary switch at \""hFE\"" position.
2.Determine whether the transistor under testing is NPN or PNP and locate the emitter, base and collector leads. Insert the leads into proper holes of the hFE socket on the front of panel.
3.Read the approximate hFE value at the test condition of base current 10uA and Vce 3V.

Audible continuity Test:
1.Connect the red test lead to the \""VΩmA\"" jack and the black test lead to the \""COM\"" jack.
2.Set range switch to \""\""position.
3.Connect test leads to two points of circuit to be tested. If continuity exists, built-in buzzer will sound.

Capacitance Measurement (special model only)
1.Set the rotary switch at desired position.
2.Before inserting capacitor under measurement into capacitance testing socket, be sure that the capacitor has been discharged fully.
3.When measuring capacitors with shorter leads , a testing adapter is provided with the meter into the capacitance testing socket on the front panel to continue measurements.
4.When testing large capacitances, note that there will be a certain time lag before the final indication.

Note:
To avoid electrical shock, remove test leads from measurement circuits before testing a transistor.
To avoid electrical shock, be sure the capacitor measuring adapter has been removed before changing to anther function measurement.
Before attempting to open the case, always be sure that test leads have been disconnected from measurement circuits.
Close case and tighten screws completely before using the meter to avoid electrical shock hazard.